Home


 

Line Heaters

Fabrication:

Heater Coils are fabricated to ANSI Code B31.3 for either sweet or sour service. The following information must be provided for proper sizing of coils:

      Gas Flow - Maximum (MMSCFD)
      Oil Flow - Maximum (BOPD)
      Water Flow - Maximum (BWPD)
      Inlet Temperature (°F)
      Outlet Temperature (°F)
      Inlet Pressure (PSIG)
      Outlet Pressure (PSIG)
      Gas Specific Gravity
      Oil Specific Gravity
      Emulsion Viscosity (° Centipoise)
      Hydrogen Sulfide (%)
      Corrosion Allowance (in.)

If the primary coil fluid is oil, water, or oil and water with minor volumes of gas, then a detailed MOL analysis is not required. If the primary coil fluid is gas, the following detailed MOL analysis must be provided:

      C1 (%)
      C2 (%)
      C3 (%)
      iC4 (%)
      nC4 (%)
      iC5 (%)
      nC5 (%)
      C6 (%)
      C7+ (%)
      N2 (%)
      CO2 (%)
Inventory:

We maintain an inventory of new and reconditioned Line Heaters, for both sweet and sour service, with capacities ranging from 250,000 BTU/HR through 2,000,000 BTU/HR. All equipment inventory is available for Sale, Rent or Rental Purchase.
 


 